A56-FR-01 Series Piston Pump Instructions

2024-03-11

1. Product Overview

The piston pump A56-FR-01 is a high-performance, high-efficiency hydraulic power equipment. It adopts advanced piston pump technology and has the characteristics of compact structure, low noise, smooth operation and long life. It is widely used in various hydraulic transmission systems to provide stable and reliable power support for various industrial equipment.

2. Main technical parameters

Rated pressure: 16 MPa.

Minimum regulated flow: 12 cm³/rev.

Direction of rotation: clockwise (viewed from the pump shaft end)

Working medium: clean hydraulic oil or hydraulic water (depending on the specific model and specifications)

Working temperature: -20℃ to +80℃ (depending on specific model and specifications)

3. Installation and use

Before installation, please ensure that the equipment meets the usage requirements and check whether the pump body, seals, etc. are intact.

The installation should be carried out according to the equipment layout diagram to ensure that the pump body is installed in the correct position to avoid vibration and impact.

When connecting the pipeline, make sure the pipeline is clean and free of impurities and particles to prevent internal wear of the pump.

Please check the oil level before use to ensure that the oil is within the specified range. The oil should be clean, free of impurities, and replaced regularly.

Before starting, a no-load test run should be carried out to check the operation of the pump. If there is any abnormality, please stop it for inspection in time.

4. Maintenance and maintenance

Check the oil level regularly to ensure that the oil is within the specified range.

Change the oil regularly to avoid oil contamination and aging.

Regularly check the wear of the pump body, seals and other components. If there is any wear, please replace it in time.

Regularly check the pipe connections to ensure good sealing and no leakage.

Clean the oil pump regularly to remove oil dirt and dust and keep the equipment tidy.

5. Troubleshooting

If the piston pump is found to be operating abnormally, it should be stopped immediately for inspection to find out the cause of the failure and deal with it.

If the pump body, seals and other components are found to be seriously worn, they should be replaced in time.

If oil contamination or aging is found, the oil should be replaced in time.

If you encounter a problem that cannot be solved, please contact the manufacturer or professional maintenance personnel for maintenance in time.

6. Precautions

Do not use this product beyond the specified operating pressure and temperature range.

Do not use unsuitable oil or mix different brands of oil.

Do not perform disassembly or repair operations while the pump is running.

Please do not change the structure and parameters of the pump body at will.


Get the latest price? We'll respond as soon as possible(within 12 hours)