Main technical parameters and installation of vane pump PV2R14-8-237-F-RAAA
The main technical parameters of PV2R14-8-237-F-RAAA vane pump are as follows: Displacement: 8cc/revolution; Pressure: 140Bar; Rotation speed: 237 rpm; Distribution plate diameter: 48mm; Drive mode: belt drive; Usage features: Vane pumps have the advantages of high pressure, smooth operation, low noise, and long life. PV2R14-8-237-F-RAAA is widely used in machinery, chemical industry, petroleum, metallurgy, light industry, textile, machine tools and general machinery and equipment industries, and can be used as an auxiliary pump to transport liquids and belts with higher viscosity. granular medium. It should be noted that during use of the PV2R14 double vane pump, good oil cleanliness should be maintained and regular maintenance should be performed to ensure its normal operation and extend its service life.
The installation steps of PV2R14-8-237-F-RAAA vane pump are as follows:
1. Check whether the pump shaft rotates flexibly and there is no jamming.
2. Install the motor and pump on the base, and use a level to correct the flatness of the base.
3. Remove the pump drive shaft and clean it.
4. During installation, lubricate the bearings and bearing seats with clean 30# mechanical oil.
5. Press the vane pump into the base while adjusting the coaxiality of the motor and pump. The coaxiality adjustment method is: fix the dial indicator on the side of the pump, make the pointer touch the transmission shaft, and then adjust the position of the motor so that the transmission shaft moves forward, backward, left and right along the axis to the minimum reading. After adjustment, tighten the anchor bolts.
6. Install the drive shaft and lock it with the lock nut.
7. Turn on the motor for turning. If the rotation is flexible and there is no jamming, the installation is qualified.
After the installation is complete, you need to pay attention to the following points:
1. Make sure the area around the pump is clean and free of debris.
2. Check whether each fastener is firm and reliable to prevent loosening.
3. Operate strictly in accordance with the operating procedures to ensure safety.
4. Regularly inspect and maintain the pump and motor to extend their service life.