Reasons and solutions for PV2R1 hydraulic oil pump not absorbing oil

2024-04-25



PV2R1 vane pump plays a vital role in industrial applications, but during use, the problem of not absorbing oil sometimes occurs. This not only affects the normal operation of the equipment, but may also cause more serious failures. Therefore, it is important to understand the reasons why the PV2R1 hydraulic oil pump does not absorb oil and the corresponding solutions.

1.Possible reasons why PV2R1 hydraulic oil pump does not absorb oil

Blockage of the oil suction pipe: Impurities or dirt in the oil suction pipe may cause the pipe to be clogged, preventing the hydraulic oil from entering the pump smoothly.

The oil level in the fuel tank is too low: The oil level in the fuel tank is too low, so that the oil pump cannot absorb enough oil when running.

Damage to the seals in the pump: Damage to the seals in the pump such as O-rings, gaskets, etc. may result in insufficient pressure within the pump and the inability to form effective oil suction force.

Motor or transmission component failure: Failure of the motor or transmission component may cause the oil pump to fail to operate properly and thus be unable to absorb oil.

2.Solutions to solve the problem of PV2R1 hydraulic oil pump not absorbing oil

Check and clean the oil suction pipeline: Check the oil suction pipeline regularly to remove impurities and dirt to ensure that the pipeline is unobstructed.

Make sure the oil level in the fuel tank is sufficient: Check the oil level in the fuel tank regularly, keep the oil level within the appropriate range, and ensure that the oil pump can absorb enough oil.

Replace damaged seals: If the seals in the pump are found to be damaged, they should be replaced in time to ensure that the pressure in the pump is normal.

Check and repair the motor or transmission parts: Conduct regular inspections on the motor and transmission parts. If any fault is found, repair or replace it in time to ensure the normal operation of the oil pump.

3.Preventive measures

In addition to dealing with problems promptly, preventive measures are equally important. The following are some suggestions to prevent the PV2R1 oil pump from not sucking oil:

Regular maintenance: Perform regular maintenance on the hydraulic oil pump, including cleaning, tightening loose parts, replacing worn parts, etc.

Use qualified oil: Make sure to use hydraulic oil that meets specifications and avoid using inferior oil or mixing different types of oil.

Strengthen inspections: Strengthen the frequency of inspections of hydraulic oil pumps to detect and deal with potential problems in a timely manner.

To sum up, the problem of PV2R1 hydraulic oil pump not absorbing oil may be caused by many reasons, but through regular inspection, maintenance and preventive measures, this problem can be effectively avoided. In actual operation, analysis and processing should be carried out according to the specific situation to ensure the normal operation of the hydraulic oil pump.